Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 391

 

Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Advertise Contacts Login 
     
ORIGINAL ARTICLE
Year : 2012  |  Volume : 53  |  Issue : 3  |  Page : 145-149

Reliability of admission cardiotocography for intrapartum monitoring in low resource setting


1 Department of Obstetrics & Gynecology, Sikkim Manipal Institute of Medical Sciences, Gangtok, Sikkim, India
2 Department of Obstetrics and Gynecology, Melaka Manipal Medical College, Melaka, Malaysia
3 Department of Pediatrics, Sikkim Manipal Institute of Medical Sciences, Gangtok, Sikkim, India

Correspondence Address:
Hafizur Rahman
Department of Obstetrics and Gynecology, Sikkim Manipal Institute of Medical Sciences, 5th Mile, Tadong, Gangtok, Sikkim
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0300-1652.104384

Rights and Permissions

Background To evaluate the role of admission cardiotocography in intrapartum patients in detecting fetal hypoxia already present and to correlate the results of admission cardiotocography with perinatal outcome. Materials and Methods: It was a cross-sectional study conducted in the Labor and Maternity ward during the period 2007-2009. The study included 176 pregnant women (both high risk and low risk), admitted to the emergency department or through the outpatient department with period of gestation ≥36 weeks, in first stage of labor with fetus in cephalic presentation. All of them were subjected to an admission test, a 20 min recording of fetal heart rate and uterine contractions on cardiotocograph machine at the time of admission. Results: The results of the admission test were 'reactive' in 82.38%, 'equivocal' in 10.22%, and 'ominous' in 7.38% women. Women with the reactive admission test had low risk of intrapartum fetal distress (6.9%) as compared to 39.9% in the equivocal and 84.6% in the ominous group (P<0.001). Incidence of moderate to thick meconium stained liqor were more in ominous (61.5%) and equivocal group (33.3%) in compared to reactive group (4.8%) (P<0.001). Incidence of NICU admission was also significantly high (62%) in babies delivered from mother with ominous test group compared to those with equivocal (28%) and reactive test (3.45%) group babies. Neonatal mortality was also seen in babies born to mothers with equivocal (5.5%) and ominous (7.6%) admission test groups. Operative delivery for fetal distress was required in only 5.5% (8 of 145) woman of the reactive group, in 27.8% (5 of 18) woman of the equivocal group and in 84.6% (11 of 13) women of the ominous group. Conclusion: The admission cardiotocography is a simple non-invasive test that can serve as screening tool to detect fetal distress already present or likely to develop and prevent unnecessary delay in intervention. The test has high specificity and can help in 'triaging' fetuses in obstetric wards of developing countries with a heavy workload and limited resources.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2860    
    Printed82    
    Emailed0    
    PDF Downloaded197    
    Comments [Add]    
    Cited by others 2    

Recommend this journal