ORIGINAL ARTICLE
Year : 2015  |  Volume : 56  |  Issue : 1  |  Page : 54-58

Application of sigma metrics for the assessment of quality control in clinical chemistry laboratory in Ghana: A pilot study


1 Department of Laboratory Technology, University of Cape Coast, Kumasi, Ghana
2 Department of Molecular Medicine, School of Medical Sciences, College of Health Sciences, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana
3 Department of Laboratory, University of Cape Coast Hospital, Cape Coast, Ghana

Correspondence Address:
Justice Afrifa
Department of Laboratory Technology, University of Cape Coast, Kumasi
Ghana
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0300-1652.149172

Rights and Permissions

Background: Sigma metrics provide a uniquely defined scale with which we can assess the performance of a laboratory. The objective of this study was to assess the internal quality control (QC) in the clinical chemistry laboratory of the University of Cape Cost Hospital (UCC) using the six sigma metrics application. Materials and Methods: We used commercial control serum [normal (L1) and pathological (L2)] for validation of quality control. Metabolites (glucose, urea, and creatinine), lipids [triglycerides (TG), total cholesterol, high-density lipoprotein cholesterol (HDL-C)], enzymes [alkaline phosphatase (ALP), alanine aminotransferase (AST)], electrolytes (sodium, potassium, chloride) and total protein were assessed. Between-day imprecision (CVs), inaccuracy (Bias) and sigma values were calculated for each control level. Results: Apart from sodium (2.40%, 3.83%), chloride (2.52% and 2.51%) for both L1 and L2 respectively, and glucose (4.82%), cholesterol (4.86%) for L2, CVs for all other parameters (both L1 and L2) were >5%. Four parameters (HDL-C, urea, creatinine and potassium) achieved sigma levels >1 for both controls. Chloride and sodium achieved sigma levels >1 for L1 but <1 for L2. In contrast, cholesterol, total protein and AST achieved sigma levels <1 for L1 but >1 for L2. Glucose and ALP achieved a sigma level >1 for both control levels whereas TG achieved a sigma level >2 for both control levels. Conclusion: Unsatisfactory sigma levels (<3) where achieved for all parameters using both control levels, this shows instability and low consistency of results. There is the need for detailed assessment of the analytical procedures and the strengthening of the laboratory control systems in order to achieve effective six sigma levels for the laboratory.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5704    
    Printed191    
    Emailed0    
    PDF Downloaded141    
    Comments [Add]    
    Cited by others 14    

Recommend this journal